Engineering Consulting Projects. Solving, correcting, and preventing structural problems. API 579 / ASME-1 Fitness for Service, CFD Analysis, Engineering Design & Analysis to ASME Section III, VIII + Codes. We perform (thermal/ transient, stress, vibration & fatigue) finite element analysis to determine structural integrity to Engineering Codes including AWS, API and ASME.

Give Tom O’Donnell a Call to Discuss your Engineering Challenges

Design of Welded Connection Between Wind Turbine Tower and Baseplate

We designed a welded connection between a wind turbine monopole tower and its supporting baseplate to meet British Standard BS EN 1993-1-9:2005 and Eurocode 3 “Design of Steel Structures”. No suitable weldment configuration was available in Eurocode 3 to meet Detail Category 80 requirements for connecting the pole to the flat base plate. A full

Design of Welded Connection Between Wind Turbine Tower and Baseplate Read More »

Structural and Fatigue Analysis of Buckled Longwall Mining Relay Bar

Relay Bar Call Tom O’Donnell, PE to Discuss Your Engineering Challenges We were asked to perform the structural integrity and fatigue life of an original and modified longwall mining relay bar. Longwall mining is used to more efficiently remove underground coal deposits in large rectangular blocks. After a “pass” of coal has been mined, the

Structural and Fatigue Analysis of Buckled Longwall Mining Relay Bar Read More »