Image of Cracked Ductwork Image 2 of Cracked Ductwork

When reinforced ductwork cracked shortly after being placed in service, we were asked to perform an extensive failure analysis. The results determined that that the ductwork was overly-constrained. Thermal breathing and bending due to a thermal gradient that existed between the top and bottom surfaces were constrained, creating high thermal stresses. We redesigned the ductwork reinforcements and the structural supports.

 

 


We perform analysis and troubleshooting services – as well as Weld Troubleshooting/ Consulting on equipment including shafts, vessels, piping and ductwork.

Give us a call – Let’s talk about your needs.

Related Projects

Forensic Investigation of Premature Weld Cracking in Stainless Steel Exhaust Ductwork
Failure Analysis and Repair of an Overpressurized Storage Tank

Similar Services

Failure Analysis Services

Resources

Publications – Heat Exchangers, Pressure Vessels, Welds and Other Applications, Fatigue, Elevated Temperature
Links to Engineering Resources