Image of Cracked Ductwork Image 2 of Cracked Ductwork

When reinforced ductwork failed shortly after being placed in service, we were asked to perform an extensive failure analysis. The results determined that that the ductwork was overly-constrained. Thermal breathing and bending due to a thermal gradient that existed between the top and bottom surfaces were constrained, creating high thermal stresses. We redesigned the ductwork reinforcements and the structural supports.
Related Projects
Forensic Investigation of Premature Weld Cracking in Stainless Steel Exhaust Ductwork
Failure Analysis and Repair of an Overpressurized Storage Tank

Similar Services
Failure Analysis Services

Resources
Publications – Heat Exchangers, Pressure Vessels, Welds and Other Applications, Fatigue, Elevated Temperature
Links to Engineering Resources

(877) 741-5500