During the delivery of a shipment of resin, damage occurred to a storage tank at a production facility in Southwestern Pennsylvania. The tank damage was apparently the result of tank overpressurization.

O’Donnell Consulting performed a failure analysis of the tank, and determined that overpressurization was due to a “blow-down” following the transfer of resin from transport tanks to the storage tank. We also inspected the tank and made recommendations on how to best repair the vessel.


 

We perform failure analysis and design of repairs on tanks, reactors, and other process equipment.
Give us a call to discuss your engineering challenges.

Related Projects

Analysis of Failed Rotary Kiln
FEA of Condensate Tanks & Nozzles
ASME B&PV Section VIII Div. 2 Code Analysis of a Feedwater Heater