Image of Cracked Ductwork Image 2 of Cracked Ductwork

We performed failure analysis on reinforced ductwork that had cracked shortly after being placed in service. The results determined that that the ductwork had been overly-constrained. Thermal breathing and bending due to a thermal gradient that existed between the top and bottom surfaces were constrained, creating high thermal stresses. We subsequently redesigned the ductwork reinforcements and the structural supports.

 

 


We perform Weld Troubleshooting/ Consulting on equipment including shafts, vessels, piping and ductwork.

Give us a call to discuss your engineering challenges.

Related Projects

Forensic Investigation of Premature Weld Cracking in Stainless Steel Exhaust Ductwork
Failure Analysis and Repair of an Overpressurized Storage Tank
Failure Analysis and Repair of Gypsum Kiln Chain

Similar Services

Failure Analysis Services

Resources

Tom O’Donnell, PE
Links to Engineering Resources

(412) 835-5007