Notice: Trying to access array offset on value of type bool in /usr/home/w1skier/public_html/wp-pcrxhe6rpq/wp-content/plugins/search-everything/config.php on line 29
Forensic Investigation of Collapsed Paper Rack Storage Facility
Rack Structure Facility
Rack Structure
Failed Welded Beam
Failed Welded 4x4 Beam
FEA Model of Rack Structure
Section of FEA Model of Rack Structure
FEA Model of Welded Beam
FEA Model of Welded Beam

Longer than two football fields and 80 feet wide, a large steel paper rack storage facility was constructed with 110 foot tall hollow steel columns to hold over 100 million pounds of pallets of paper products. After two months in service, the automated facility collapsed and sparked a fire that burned over three weeks. We were asked to perform a forensic investigation of the collapse.

Non-destructive evaluations including visual, ultrasonic (UT) and radiographic techniques were used to assess the condition of the structural square tubes and to assist in the selection of specimens for defect evaluation. All of the damaged tubes submitted for evaluation exhibited extensive linear weld seam tears in deformed regions.

We also performed finite element analysis on individual beams, as well as a segment of the entire rack structure.

The failure mode was determined to be flexural torsional buckling of the 4″ x 4″ welded steel columns. The result of the litigation was $64 M in favor of our client. Read about it here.


 

We perform engineering design and analysis – as well as forensic engineering services.
Give us a call – Let’s talk about your needs.

Related Projects

$200 M Litigation – Engineering Analysis on Coke Oven Battery Construction Issues
Engineering Analysis of Design Errors in Electrostatic Precipitator