FEA Analysis of FRP Piping in Flue Gas Desulfurization System

Structural Analysis of FRP Piping System using FEA

Three-Dimensional Finite Element Model of Piping System

Structural Analysis of FRP Piping System using FEA
(ANSYS) Finite Element Model of FRP Piping

Structural (FEA) analysis of Fiberglass Reinforced Plastic Piping (FRP) for use in a Flue Gas Desulfurization System that was installed at a power plant in Vietnam.

The desulfurization system piping is subject to thermal and pressure loadings, as well as self-weight, contained fluid weight, operational forces, wind loads and potential seismic events.

To investigate the behavior of the recycle slurry piping, we created a three-dimensional finite element model using ANSYS. Four separate piping runs, designated according to their associated recycle pump identification number comprise the external portion of the recycle slurry piping. Each piping run is similar in layout and geometry, but has differences at the beginning and termination of each run.

The following methodology and assumptions were used:
1) Small diameter drain lines and vents attached to the large diameter piping was not included in the finite element model(s).
2) Valves and pumps were not included in the models.
3) Flange and field joints were not explicitly included in the piping models.
4) The piping is supported at various locations with vertical spring hangers. The springs were assumed to resist movements in the vertical direction only.
5) Expansion joints were model with a combination of beams, springs, and gap elements.
6) All material behavior was assumed to be linear elastic.
7) The allowable axial stress is based on an ultimate tensile strength of the FRP piping of 9000 psi.
8) Design pressure = 60 psi


 

O’Donnell Consulting Engineers Performs Design and Analysis for Clients in Industries including Petrochemical, Mining and Energy.